No blower no air! In industrial processes one blower can often supply several air heaters in parallel. Our durable and maintenance-free blowers are a result of uncompromising quality standards and decades of experience. SILENCE, Leister’s mid-range blower, is very quiet during operation at 61 dB(A). Developed to withstand operating conditions with air intake temperatures of 100° C to 200° C (212 °F to 392 °F). Delivers optimum & effortless performance in ambient temperatures up to 75° C (167 °F).
SILENCE
Very quiet operation with 61 dB(A). Large air volumes and can be installed in all positions.
Technical Data
SILENCE – 3 x 230/400 V / 50 Hz / without cord
Attribute | Unit | Value |
---|---|---|
Frequency | Hz | 50 |
Voltage | V~ | 3 x 230/400 |
Air volume (20°C) | l/min | 6000 |
Pressure static | kPa | 1.4 |
Power | W | 250 |
Ambient temperature | °C | 65 … 75 |
Air inlet temperature | °C | 100 … 200 |
Noise emission level | dB(A) | 61 |
Environmental protection | IEC 60529 | IP 54 |
Outside diameter air inlet | mm | 80 |
Air outlet (external) | mm | 60 |
Weight | kg | 9.0 |
Conformity mark | ||
Protection class I |
SILENCE – 3 x 440/480 V / 60 Hz / without cord
Attribute | Unit | Value |
---|---|---|
Frequency | Hz | 60 |
Voltage | V~ | 3 x 440/480 |
Air volume (20°C) | l/min | 6000 |
Pressure static | kPa | 1.4 |
Power | W | 250 |
Ambient temperature | °C | 65 … 75 |
Air inlet temperature | °C | 100 … 200 |
Noise emission level | dB(A) | 61 |
Environmental protection | IEC 60529 | IP 54 |
Outside diameter air inlet | mm | 80 |
Air outlet (external) | mm | 60 |
Weight | kg | 9.0 |
Conformity mark | ||
Protection class I |
SILENCE – 1 x 230 V / 50 Hz / EU-Plug
Attribute | Unit | Value |
---|---|---|
Frequency | Hz | 50 |
Voltage | V~ | 1 x 230 |
Air volume (20°C) | l/min | 4700 |
Pressure static | kPa | 1.0 |
Power | W | 250 |
Ambient temperature | °C | 65 … 75 |
Air inlet temperature | °C | 100 … 200 |
Noise emission level | dB(A) | 61 |
Environmental protection | IEC 60529 | IP 54 |
Outside diameter air inlet | mm | 80 |
Air outlet (external) | mm | 60 |
Weight | kg | 9.0 |
Conformity mark | ||
Protection class I |
Downloads
General Catalogs :
GC – General Catalog Process Heat (7,95 MB)
Brochures :
BR – Blowers (2,93 MB)
BR – Process Heat – useful formulas (0,05 MB)
Manuals :
BA – ASO, SILENCE, RBR (8,92 MB)
สินค้าที่เกี่ยวข้อง
Wide array of applications. Detection of heating element and device overheating with alarm output.
Smallest of the LHS Series. Remote control interface for Leister CSS or SPS temperature controller.
Energy savings effect thanks to hot air recirculation. Maximum air inlet temperature of 350 °C/ 662°F.
Energy savings effect thanks to hot air recirculation. Maximum air inlet temperature 350 °C / 662°F.
Smallest of the LHS Series. Detection of heating element and device overheating with alarm output.
Energy savings effect thanks to hot air recirculation. Maximum air inlet temperature of 150°C / 302°F.