[Heaters]
LE 5000 DF-R
Download
General Catalogs
GC - General Catalog Process Heat
Manuals
BA - LE 5000 DF-R / 10000 DF-R
Brochures
BR - Blowers
BR - Process Heat - useful formulas
CAD-Files
Drawings - LE 5000 DF-R
 
  • Easy to integrate into existing air systems
  • Suitable for recycling air
  • Simple and safe fixture options
  • No integrated power electronics 
The latest generation of double-flange air heaters is specially designed to be used in hot-air recirculation mode. Depending on the air inlet and air outlet temperature, a massive amount of energy can be saved by “recycling“ hot-air. On the inlet side, the device can easily tolerate temperatures up to 350°C.

 

Specifications
LE 5000 DF-R - 3 x 400 V / 4.5 kW
Article No.: 146.480
Attribute Unit Value
Voltage V~ 3 x 400
Power W 4500
Max. air outlet temperature °C 700
Min. air volume (20°C) Nl/min - 4.5 kW 310
Max. air inlet temperature °C 350
Max. ambient temperature °C 200
Size (L x ∅) mm 184 × 116
Weight kg 2.0
Conformity mark   CE Certification
Protection class I   Protection Class I

LE 5000 DF-R - 3 x 400 V / 6.5 kW
Article No.: 146.794
Attribute Unit Value
Voltage V~ 3 x 400
Power W 6500
Max. air outlet temperature °C 700
Min. air volume (20°C) Nl/min - 6.5 kW 450
Max. air inlet temperature °C 350
Max. ambient temperature °C 200
Size (L x ∅) mm 184 × 116
Weight kg 2.0
Conformity mark   CE Certification
Protection class I   Protection Class I

LE 5000 DF-R - 3 x 400 V / 7.5 kW
Article No.: 146.795
Attribute Unit Value
Voltage V~ 3 x 400
Power W 7500
Max. air outlet temperature °C 700
Min. air volume (20°C) Nl/min - 7.5 kW 510
Max. air inlet temperature °C 350
Max. ambient temperature °C 200
Size (L x ∅) mm 184 × 116
Weight kg 2.0
Conformity mark   CE Certification
Protection class I   Protection Class I
 
 

 